What are the recommendations for the maintenance cycle of the new energy explosion-proof valve at extreme temperatures?


The maintenance cycle of the new energy explosion-proof valve under extreme temperatures is recommended as follows:

1. In high temperature environment, the maintenance cycle of explosion-proof valve should be appropriately shortened to prevent damage to the valve body and seals caused by high temperature. It is recommended to carry out maintenance inspection every 3 months.

2. In the low temperature environment, the maintenance cycle of the explosion-proof valve should also be shortened to prevent the seal from hardening, breaking or losing elasticity due to low temperature. It is recommended to carry out maintenance inspection every 3 months.

3. In the environment of extreme temperature fluctuations, the maintenance cycle of the explosion-proof valve should be more frequent to prevent temperature changes from causing damage to the valve body and seals. It is recommended to perform a maintenance check every 2 months.

4. Regardless of the temperature environment, the sealing performance of the explosion-proof valve, the corrosion of the valve body, and the normal operation of the poppet valve should be checked regularly. If a problem is found, it should be maintained or replaced in time.

5. During maintenance, appropriate tools and methods should be used to avoid secondary damage to the explosion-proof valve.

The maintenance cycle should be adjusted according to actual usage and environmental conditions. If the performance of the explosion-proof valve is found to be degraded or malfunctioning, the manufacturer or professional maintenance personnel should be consulted in time for maintenance.

In short, when using new energy explosion-proof valves under extreme temperatures, more attention should be paid to their maintenance cycles and inspection items to ensure the normal operation and safety of explosion-proof valves.

Related News


What are the obvious signs of the aging of the seals of the waterproof ventilation valve?

Degradation of the seal of the waterproof vent valve may cause the following obvious signs:


Waterproof ventilation valve maintenance matters needing attention

Waterproof ventilation valve is a commonly used protective component in electronic equipment, which is used to prevent moisture and dust from entering the inside of the equipment, while allowing the free flow of gas. The following are some of the waterproof ventilation valve maintenance considerations:


What are the recommend tools for de-icing the external icing of the valve body?

In cold conditions, ice may form on the outside of the valve body. In order to effectively remove the ice layer, the following recommend of tools can be used:


What is waterproof ventilation valve?

The waterproof ventilation valve is a device that can realize the outward expansion of water molecules and the expansion of gas in the sealed state of the object. It is mainly composed of waterproof breathable membrane, valve body and valve core and other components, in which the waterproof breathable membrane occupies its main production cost. There are many kinds of waterproof ventilation valves, which can be divided into metal waterproof ventilation valves and plastic waterproof ventilation valves according to different materials. According to different installation methods, it can be divided into snap-in waterproof ventilation valve, threaded waterproof ventilation valve, press-in waterproof ventilation valve, etc. According to different gas flow directions, it can be divided into two-way waterproof ventilation valve and one-way waterproof ventilation valve. According to different connection methods, it can be divided into welding type waterproof breathable valve, injection molding type waterproof breathable valve, bonding type waterproof breathable valve, etc.


How long is the maintenance cycle of waterproof ventilation valve?

The maintenance cycle of the waterproof ventilation valve varies with the use environment and frequency, but it is usually recommended to check at least once a year. The following are some recommended maintenance steps:


When the waterproof ventilation valve is damaged, what are the quick judgment methods?

When the waterproof ventilation valve is damaged, the problem can be identified by the following quick judgment methods: